Differential Pressure Flow Elements
Differential pressure used to determine the flow rate is one of the oldest and widely used technique of flow measurement. Differential pressure is generated by creating obstruction to the moving flow. The pressure difference created is measured through pressure taps provided on upstream and downstream side of obstruction. This differential pressure can be measured using devices like manometer or DP transmitter. Based on the differential pressure value, the flow rate is calculated.
Orifice Plates & Flanges
- Available from 15 to 1000 mm
- Design as per ISO 5167-2 standard
- MOC: SS 304/316, Monel, Hast alloy, Teflon
- Installed between ASME B 16.36 flanges
- Wide options of flow elements to select based on process requirements
- Maintenance free
- Sizing calculations available for determination of various parameters
- Calibration can be carried out within limitations of laboratory
- DP flow elements are used for flow measurement in almost all industries including Power, Chemicals, Petrochemicals, refineries, Gas plants, Water treatment etc.
- Normally used in combination with DP Transmitter for flow measurement. The DP transmitter signal can be connected to PLC or other control system
Orifice Plates & Flanges
- Available from 15 to 1000 mm
- Flange rating from 300# class onwards up to 2500#
- Complete assembly consisting of Orifice Plate, Weld neck flanges, gasket and hardware
- Upstream/downstream Pressure Taps drilled on flanges
- MOC: Carbon steel, Stainless steel
- Gaskets: Spiral wound or NACF sheet
- Hardware: MS Graded or Stainless steel
- Wide options of flow elements to select based on process requirements
- Maintenance free
- Sizing calculations available for determination of various parameters
- Calibration can be carried out within limitations of laboratory
- DP flow elements are used for flow measurement in almost all industries including Power, Chemicals, Petrochemicals, refineries, Gas plants, Water treatment etc.
- Normally used in combination with DP Transmitter for flow measurement. The DP transmitter signal can be connected to PLC or other control system
Restriction Orifice Plates and Assemblies
- Used for creating desired pressure loss in the system
- Single or multistage design
- Single, multi hole design options
- Hard facing option available
- End connection: Buttweld able or flanged end
- MOC: Plates in Stainless steel, holding flange or pipe can be in Carbon, Mild steel or stainless steel
- Wide options of flow elements to select based on process requirements
- Maintenance free
- Sizing calculations available for determination of various parameters
- Calibration can be carried out within limitations of laboratory
- DP flow elements are used for flow measurement in almost all industries including Power, Chemicals, Petrochemicals, refineries, Gas plants, Water treatment etc.
- Normally used in combination with DP Transmitter for flow measurement. The DP transmitter signal can be connected to PLC or other control system