Bye pass Rotameter with Carrier ring (BPC series)
Bye pass rotameters are used for measurement of higher flow rates when using inline flow meter is not possible. It works on the principle of measuring differential pressure created across restriction.The construction includes an orifice plate installed between either carrier ring or orifice/pipe flanges. The Hi/Low pressure taps of carrier ring/orifice flange/ pipe are connected to indicating Rotameter with a help of impulse tube arrangement. The Indicating Rotameter can be of Glass or Metal tube Type.
BPC
- Primary Element: Orifice plate with Carrier ring
- MOC: Orifice Plate: SS 316
- Carrier Ring: CF8, CF8M, AISI SS 316, 304, PTFE
- Indicating Rotameter: SS 316 for Metal Tube Rotameter, MS/CS/SS for Glass tube Rotameter
- Holding flanges: As per ANSI B 16.5
- line size: 2” to 16”
- Pressure Tap: Corner Taps on carrier ring
- Accuracy: +/-2% FS
- Rangeability: 5:1 or 3:1 depending on Indicating Rotameter
- Variety of installation styles
- Rangeability: 1:5 for Glass tube and 1:3 for metal tube
- Differential pressure can be selected based on operating pressure
- Can be offered with Electrical transmitter
- Both Glass tube and Metal Tube Rotameters can be used for flow rate indication purpose
- Electrical Transmitter output possible
- Used for measurement of flow rates in higher pipe sizes.
- The common application is measurement of water flow in water treatment plants.
- Can also be used for measurement of air/gaseous fluid flow.
BPF
- Primary Element: Orifice plate
- MOC: Orifice Plate: SS 316
- Orifice Flanges: CF8, CF8M, AISI SS 316, 304, PTFE
- Indicating Rotameter: SS 316 for Metal Tube Rotameter, MS/CS/SS for Glass tube Rotameter
- Flange standard: As per ANSI B 16.36
- Line size: 2” to 16”
- Pressure Tap: Flange Taps on Orifice Flange
- Accuracy: +/-2% FS
- Rangeability: 5:1 or 3:1 depending on Indicating Rotameter
- Variety of installation styles
- Rangeability: 1:5 for Glass tube and 1:3 for metal tube
- Differential pressure can be selected based on operating pressure
- Can be offered with Electrical transmitter
- Both Glass tube and Metal Tube Rotameters can be used for flow rate indication purpose
- Electrical Transmitter output possible
- Used for measurement of flow rates in higher pipe sizes.
- The common application is measurement of water flow in water treatment plants.
- Can also be used for measurement of air/gaseous fluid flow.
BPD
- Primary Element: Orifice plate
- MOC: Orifice Plate: SS 316
- Indicating Rotameter: SS 316 for Metal Tube Rotameter, MS/CS/SS for Glass tube Rotameter
- Holding flanges: As per ANSI B 16.5
- line size: 2” to 16”
- Pressure Tap: D,D/2 tapping on process pipe
- Accuracy: +/-2% FS
- Rangeability: 5:1 or 3:1 depending on Indicating Rotameter
- Variety of installation styles
- Rangeability: 1:5 for Glass tube and 1:3 for metal tube
- Differential pressure can be selected based on operating pressure
- Can be offered with Electrical transmitter
- Both Glass tube and Metal Tube Rotameters can be used for flow rate indication purpose
- Electrical Transmitter output possible
- Used for measurement of flow rates in higher pipe sizes.
- The common application is measurement of water flow in water treatment plants.
- Can also be used for measurement of air/gaseous fluid flow.